Understanding Biological Contamination in Cooling Towers

masthead-logo-icon

When cooling tower efficiency drops or a Legionella alert arises, biological contamination may be the culprit. The environment inside the cooling tower is prime for biological growth — warm, nutrient-rich water provides an ideal breeding ground where a single bacterial cell can multiply into millions in just hours. Understanding the issue, its causes and impacts, and how to address it effectively can help you design a risk-mitigation strategy for your facility.

What Is Biological Contamination?

Biological contamination is the growth of microorganisms in the water system. These contaminants, like fungi, algae and bacteria, form on surfaces that contact the water, creating a slime that’s challenging to eradicate. Each behaves slightly differently and poses different risks. 

Types of Biological Contaminants

Knowing the contaminant type and activity helps you target your control efforts to the specific issue.

Bacteria

Bacteria are microscopic, single-celled organisms that reproduce independently, allowing them to colonize areas very quickly. There are two primary types you’ll encounter in cooling tower biological control — planktonic and sessile. Planktonic bacteria are free-swimming microorganisms that float in the water, while sessile bacteria permanently anchor themselves to a structure and form a biofilm.

This film encases and protects potentially dangerous pathogens like Legionella, which can also alternate between the two types. Once embedded in biofilm, Legionella thrives on the nutrients and protection it provides against disinfectants, making it especially difficult to eliminate. In favorable cooling tower environments, Legionella populations can double every three to four hours.

Algae

Algae pose challenges in cooling towers with infrastructure exposed to sunlight or the atmosphere, where light penetration supports photosynthesis. Unlike bacteria, they’re often visible as green or brown slime, typically accumulating within the tower fill and basin.

These microorganisms create a biomass that can quickly clog systems, blocking water flow and distribution and leading to reduced cooling efficiency.

Fungi

While they also grow in moist environments, fungi are usually the least commonly identified biological contaminants in a water test. This lower frequency of occurrence tends to make them less problematic overall.

Cooling systems that feature wooden fill, structural supports or drift eliminators are more susceptible to fungi formation, which can cause rot and structural deterioration. Modern cooling towers often use nonwood materials, potentially reducing the risk of fungal growth.

Why Biological Contamination Occurs

Several conditions make cooling towers ideal environments for biological growth.

Warm Water Temperature

Water temperatures in cooling towers can range from 104° Fahrenheit (40° Celsius) at the inlet to 89.6° Fahrenheit (32° Celsius) at the outlet — a range at which many contaminants thrive or grow:

Nutrient Availability

Nutrient-rich water substantially contributes to a favorable environment for microorganism growth. Dead microbial cells or biomass and airborne debris like pollen, dust, leaves and dirt entering the tower provide food for reproduction.

Process contamination is also a factor. Manufacturing byproducts — hydrocarbons, sugars, proteins, chemicals — entering the cooling water can cause nutrient spikes that accelerate biological growth.

Oxygen and Sunlight

Cooling tower design naturally relies on air contact for evaporative cooling, which means the system constantly circulates an abundant supply of oxygen for bacterial colonization and multiplication. Open tower designs also allow sunlight penetration, supporting algae growth.

Inadequate Treatment

Because cooling towers create such a favorable environment for biological contamination, treatment is never a one-time fix. High total organic carbon (TOC) and biochemical oxygen demand (BOD) often indicate that your protocols aren’t keeping pace with contamination and may result from:

  • Irregular dosing or application schedules, leading to treatment gaps that allow populations to rebound quickly.
  • Underdosing biocides, which creates resistance.
  • Using the wrong biocide for the type of microorganisms present.
  • Lack of rotation between oxidizing and nonoxidizing biocides.
  • Infrequent biological testing of cooling tower water.

Impact on Cooling Tower and Operational Performance

Cooling tower water contamination negatively affects your equipment performance and operations in several key ways.

Health and Compliance Risks

Bacterial colonization can lead to aerosol transmission of Legionnaires’ disease, which has more than 6,000 reported cases annually in the United States. About one in every 10 will die from complications, with the rate soaring to 25% of those who develop the disease in a healthcare facility.

The circulation of contaminated water can lead to Legionella outbreaks, creating legal liability or regulatory penalties. Improper water management protocols may also violate ASHRAE 188 and state laws in jurisdictions like New York and New Jersey, with costly penalties for noncompliance.

Reduced Efficiency

Biofilm formation on heat-exchange surfaces acts as insulation, preventing efficient heat transfer between the water and the air. A layer as thin as 0.1 millimeters can cause a corresponding 30% to 50% drop in thermal conductivity in some tower designs.

As the biofilm thickens, cooling capacity declines and energy consumption increases to compensate for reduced performance. The system must work harder to achieve the same cooling output, driving up operational costs while delivering diminished results. 

Equipment Damage

Biological contamination accelerates equipment deterioration in multiple ways. Algae and bacterial biomass clog distribution nozzles, tower fill and basin screens, restricting water flow and reducing system effectiveness. Microbiologically influenced corrosion occurs when bacteria create localized conditions beneath biofilms that attack metal surfaces, causing pitting, leaks and premature equipment failure.

Microbial Control Overview

Addressing biological contamination requires a comprehensive approach rather than a single solution. Effective control programs combine three key elements:

  • Chemical treatment: Biocide programs use oxidizing and nonoxidizing agents to control microbial growth.
  • Regular monitoring: Consistent biological testing of cooling tower water identifies contamination early and tracks treatment effectiveness, enabling intervention before issues escalate.
  • Optimized system design: Proper tower configuration, water flow patterns and materials selection can reduce conditions that promote biological growth.

Protect Your Cooling Tower Systems With Chardon Laboratories

Chardon Labs provides professional cooling tower water treatment services designed to manage biological contamination through customized programs, regular testing and expert technical support. Contact us to discuss a water management solution for your facility.

Protect Your Cooling Tower Systems With Chardon Laboratories
Avatar photo

Matt Welsh

Matt Welsh is the Vice President and Water Consultant at Chardon Labs. He helps consult a wide range of customers utilizing various methods of water treatment, from chemical to chemical-free approaches, large and small applications, and across a wide range of geographical influences. With 20 years of water treatment experience, including a wide range of troubleshooting and service in potable water and non-potable HVAC and industrial applications, he is an expert in water treatment chemistry for cooling towers, boilers, and closed-loop systems.

Previous ArticleCorrosion and Microbial Growth in Closed Loop Systems